Model: |
HP-MX |
Categories: |
Pressure Transmitter |
Description: |
|
|
Intrinsically safe pressure
transmitter for industrial use |
|
|
|
|
Electrical Data |
Max. measuring range |
1…2000 bar |
Overload pressure |
6…1200 bar(depending on
the Max. measuring range) |
Burst pressure |
9…1500 bar(depending on
the Max. measuring range) |
Output signal |
4…20 mA |
Supply voltage |
9…27 V |
Response time |
<1 ms |
Accuracy |
≤0.50%,(optional ≤0.25%) |
Mechanical Data |
Housing |
Stainless steel |
Parts in contact with
the measuring medium |
Stainless steel |
Shock resistance |
1000 g |
Vibration resistance |
20 g |
Measuring medium
temperature |
-40℃…+85℃
|
Ambient temperature |
-40℃…+85℃ |
Storage temperature |
-40℃…+125℃ |
Protection |
IP65(special version up to IP69K) |
Connector |
M12×1; MVS/A; MVS/C; Cable * |
Pressure connection |
G 1/4 A, Form E; G1/4 B;G1/2 B; 1/4 NPT * |
Directive ATEX
Type of ignition protection |
II 2G Ex ia IIC T4
(IBExU 04 ATEX 1182) |
Underlying standards |
EN 50014, EN 50020 |
*Custom-made adjustments acc. to pressure connections and connecting options are possible. |
[Back] |